TMA500-MP
Electromechanical Actuator 500 Pound Capacity

SPB 6405 - 115 VAC with clutch
SPB 7405 - 220 VAC with clutch
HSPB 6405 - 115 VAC High Speed with clutch

Additional Information

Stroke Lengths 3, 6, 12, and 18 inch, 75, 150, 300, 450 mm
Motor Protection Automatic reset thermal overload in motor
Temperature Range -20°F. to 104°F Ambient -29°C to 40°C
Drive Double Lead Screw
Housing Aluminum alloy
Standard Mounting Double Clevis
Cable Entrance 1/2" NPT
Clutch Load limiting friction disc
Restraining Torque 60 in lbs, 6.78 N-m
Brake Bi-Directional Ball Type

115 VAC motor is an enclosed, permanent split capacitor induction type.  The motor is equipped with a thermal overload device that opens and resets automatically.  Standard motor requires 28-33 mfd capacitor supplies by either the customer, or Duff-Norton at extra cost, for loads up to 250 pounds.  High speed motors require a 64-72 mfd capacitor, also available from Duff-Norton.  A capacitor box is available on AC models only. 

220 VAC motor is totally enclosed, permanent split capacitor induction type.  Load/no-load speeds are approximately equal.  Equipped with thermal overload device that opens and resets automatically.  Standard motor requires 10 mfd 440VAC, 60/50Hz metalized polypropylene capacitor supplied by Duff-Norton. 

Controls are also available for these actuator models as follows:

  • For SPB6405 - Use BAC-1C Control Package
  • For SPB7405 - Use BAC-2C Control Package

Additional Notes

  • Some actuator surface temperatures may reach 230°F at or near maximum allowable duty cycle.
  • The thermal overload resets in 10 minutes.
  • All ratings are normal and based on the actuator being broken in for approximately 2500 inches of travel.

Dimensions