(Type 1)
A. Overall diameter
B. Bolt circle diameter
K. Rotary Union®
joint shaft thread size and direction
L Size of bolt holes
M. Type and size of bolts
N. Number of bolt holes required |
|
|
|
Flanged Housing with Counterbore
(Type 2)
A. Overall diameter
B. Bolt circle diameter
C. O.D. of journal for sizing counterbore diameter
D. Counterbore depth
K. Rotary Union®
joint shaft thread size and direction
L. Size of bolt holes
M. Type and size of bolts
N. Number of bolt holes required |
|
|
|
Flanged Housing with Pilot
(Type 3)
A. Overall diameter
B. Bolt circle diameter
K. Rotary Union®
joint shaft thread size and direction
L. Size of bolt holes
M. Type and size of bolts
N. Number of bolt holes required
P. I.D. of journal for sizing pilot diameter
R. Pilot length |
|
|
|
Bolt and Flange
Dimension
|
| Shaft
I.D. |
Minimum
Bolt Circle |
Maximum
Flange Dia. A |
Maximum
Flange Thickness |
| Bolt
Circle B |
Cap
Screw Dia. |
| 2" |
7
1/8"
184mm |
5/8" |
10
7/8"
276mm |
1
7/16"
37mm |
| 3" |
7
9/16"
192mm |
5/8" |
13
1/2"
343mm |
1
3/4"
44mm |
| 4" |
8
15/16"
227mm |
3/4" |
14
7/8"
378mm |
2
1/16"
52mm |
| 5" |
11
9/16"
293.6mm |
1" |
16
1/4"
413mm |
2
3/4"
70mm |
|